Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 671
Filtrar
1.
Cancers (Basel) ; 16(7)2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38610957

RESUMO

PURPOSE: Evaluation of the influence of intrinsic and extrinsic conditions on ablation zone volumes (AZV) after microwave ablation (MWA). METHODS: Retrospective analysis of 38 MWAs of therapy-naïve liver tumours performed with the NeuWave PR probe. Ablations were performed either in the 'standard mode' (65 W, 10 min) or in the 'surgical mode' (95 W, 1 min, then 65 W, 10 min). AZV measurements were obtained from contrast-enhanced computed tomography immediately post-ablation. RESULTS: AZVs in the 'standard mode' were smaller than predicted by the manufacturer (length 3.6 ± 0.6 cm, 23% below 4.7 cm; width 2.7 ± 0.6, 23% below 3.5 cm). Ablation zone past the tip was limited to 6 mm in 28/32 ablations. Differences in AZV between the 'surgical mode' and 'standard mode' were not significant (15.6 ± 7.8 mL vs. 13.9 ± 8.8 mL, p = 0.6). AZVs were significantly larger in case of hepatocellular carcinomas (HCCs) (n = 19) compared to metastasis (n = 19; 17.8 ± 9.9 mL vs. 10.1 ± 5.1 mL, p = 0.01) and in non-perivascular tumour location (n = 14) compared to perivascular location (n = 24, 18.7 ± 10.4 mL vs. 11.7 ± 6.1 mL, p = 0.012), with both factors remaining significant in two-way analysis of variance (HCC vs. metastasis: p = 0.02; perivascular vs. non-perivascular tumour location: p = 0.044). CONCLUSION: Larger AZVs can be expected in cases of HCCs compared with metastases and in non-perivascular locations. Using the 'surgical mode' does not increase AZV significantly.

2.
J Nucl Med ; 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38604763

RESUMO

PET using 68Ga-labeled fibroblast activation protein (FAP) inhibitors (FAPIs) holds high potential for diagnostic imaging of various malignancies, including lung cancer (LC). However, 18F-FDG PET is still the clinical gold standard for LC imaging. Several subtypes of LC, especially lepidic LC, are frequently 18F-FDG PET-negative, which markedly hampers the assessment of single pulmonary lesions suggestive of LC. Here, we evaluated the diagnostic potential of static and dynamic 68Ga-FAPI-46 PET in the 18F-FDG-negative pulmonary lesions of 19 patients who underwent surgery or biopsy for histologic diagnosis after PET imaging. For target validation, FAP expression in lepidic LC was confirmed by FAP immunohistochemistry. Methods: Hematoxylin and eosin staining and FAP immunohistochemistry of 24 tissue sections of lepidic LC from the local tissue bank were performed and analyzed visually. Clinically, 19 patients underwent static and dynamic 68Ga-FAPI-46 PET in addition to 18F-FDG PET based on individual clinical indications. Static PET data of both examinations were analyzed by determining SUVmax, SUVmean, and tumor-to-background ratio (TBR) against the blood pool, as well as relative parameters (68Ga-FAPI-46 in relation to18F-FDG), of histologically confirmed LC and benign lesions. Time-activity curves and dynamic parameters (time to peak, slope, k 1, k 2, k 3, and k 4) were extracted from dynamic 68Ga-FAPI-46 PET data. The sensitivity and specificity of all parameters were analyzed by calculating receiver-operating-characteristic curves. Results: FAP immunohistochemistry confirmed the presence of strongly FAP-positive cancer-associated fibroblasts in lepidic LC. LC showed markedly elevated 68Ga-FAPI-46 uptake, higher TBRs, and higher 68Ga-FAPI-46-to-18F-FDG ratios for all parameters than did benign pulmonary lesions. Dynamic imaging analysis revealed differential time-activity curves for LC and benign pulmonary lesions: initially increasing time-activity curves with a decent slope were typical of LC, and steadily decreasing time-activity curve indicated benign pulmonary lesions, as was reflected by a significantly increased time to peak and significantly smaller absolute values of the slope for LC. Relative 68Ga-FAPI-46-to-18F-FDG ratios regarding SUVmax and TBR showed the highest sensitivity and specificity for the discrimination of LC from benign pulmonary lesions. Conclusion: 68Ga-FAPI-46 PET is a powerful new tool for the assessment of single 18F-FDG-negative pulmonary lesions and may optimize patient stratification in this clinical setting.

3.
Dtsch Arztebl Int ; (Forthcoming)2024 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-38530931

RESUMO

BACKGROUND: Population-wide research on potential new imaging biomarkers of the kidney depends on accurate automated segmentation of the kidney and its compartments (cortex, medulla, and sinus). METHODS: We developed a robust deep-learning framework for kidney (sub-)segmentation based on a hierarchical, three-dimensional convolutional neural network (CNN) that was optimized for multi-scale problems of combined localization and segmentation. We applied the CNN to abdominal magnetic resonance images from the population-based German National Cohort (NAKO) study. RESULTS: There was good to excellent agreement between the model predictions and manual segmentations. The median values for the body-surface normalized total kidney, cortex, medulla, and sinus volumes of 9934 persons were 158, 115, 43, and 24 mL/m2. Distributions of these markers are provided both for the overall study population and for a subgroup of persons without kidney disease or any associated conditions. Multivariable adjusted regression analyses revealed that diabetes, male sex, and a higher estimated glomerular filtration rate (eGFR) are important predictors of higher total and cortical volumes. Each increase of eGFR by one unit (i.e., 1 mL/min per 1.73 m2 body surface area) was associated with a 0.98 mL/m2 increase in total kidney volume, and this association was significant. Volumes were lower in persons with eGFR-defined chronic kidney disease. CONCLUSION: The extraction of image-based biomarkers through CNN-based renal sub-segmentation using data from a population-based study yields reliable results, forming a solid foundation for future investigations.

4.
Front Med (Lausanne) ; 11: 1360706, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38495118

RESUMO

Background: Chronic obstructive pulmonary disease (COPD) poses a substantial global health burden, demanding advanced diagnostic tools for early detection and accurate phenotyping. In this line, this study seeks to enhance COPD characterization on chest computed tomography (CT) by comparing the spatial and quantitative relationships between traditional parametric response mapping (PRM) and a novel self-supervised anomaly detection approach, and to unveil potential additional insights into the dynamic transitional stages of COPD. Methods: Non-contrast inspiratory and expiratory CT of 1,310 never-smoker and GOLD 0 individuals and COPD patients (GOLD 1-4) from the COPDGene dataset were retrospectively evaluated. A novel self-supervised anomaly detection approach was applied to quantify lung abnormalities associated with COPD, as regional deviations. These regional anomaly scores were qualitatively and quantitatively compared, per GOLD class, to PRM volumes (emphysema: PRMEmph, functional small-airway disease: PRMfSAD) and to a Principal Component Analysis (PCA) and Clustering, applied on the self-supervised latent space. Its relationships to pulmonary function tests (PFTs) were also evaluated. Results: Initial t-Distributed Stochastic Neighbor Embedding (t-SNE) visualization of the self-supervised latent space highlighted distinct spatial patterns, revealing clear separations between regions with and without emphysema and air trapping. Four stable clusters were identified among this latent space by the PCA and Cluster Analysis. As the GOLD stage increased, PRMEmph, PRMfSAD, anomaly score, and Cluster 3 volumes exhibited escalating trends, contrasting with a decline in Cluster 2. The patient-wise anomaly scores significantly differed across GOLD stages (p < 0.01), except for never-smokers and GOLD 0 patients. In contrast, PRMEmph, PRMfSAD, and cluster classes showed fewer significant differences. Pearson correlation coefficients revealed moderate anomaly score correlations to PFTs (0.41-0.68), except for the functional residual capacity and smoking duration. The anomaly score was correlated with PRMEmph (r = 0.66, p < 0.01) and PRMfSAD (r = 0.61, p < 0.01). Anomaly scores significantly improved fitting of PRM-adjusted multivariate models for predicting clinical parameters (p < 0.001). Bland-Altman plots revealed that volume agreement between PRM-derived volumes and clusters was not constant across the range of measurements. Conclusion: Our study highlights the synergistic utility of the anomaly detection approach and traditional PRM in capturing the nuanced heterogeneity of COPD. The observed disparities in spatial patterns, cluster dynamics, and correlations with PFTs underscore the distinct - yet complementary - strengths of these methods. Integrating anomaly detection and PRM offers a promising avenue for understanding of COPD pathophysiology, potentially informing more tailored diagnostic and intervention approaches to improve patient outcomes.

5.
BMC Pulm Med ; 24(1): 103, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38424530

RESUMO

BACKGROUND: Randomized controlled trials described beneficial effects of inhaled triple therapy (LABA/LAMA/ICS) in patients with chronic obstructive pulmonary disease (COPD) and high risk of exacerbations. We studied whether such effects were also detectable under continuous treatment in a retrospective observational setting. METHODS: Data from baseline and 18-month follow-up of the COPD cohort COSYCONET were used, including patients categorized as GOLD groups C/D at both visits (n = 258). Therapy groups were defined as triple therapy at both visits (triple always, TA) versus its complement (triple not always, TNA). Comparisons were performed via multiple regression analysis, propensity score matching and inverse probability weighting to adjust for differences between groups. For this purpose, variables were divided into predictors of therapy and outcomes. RESULTS: In total, 258 patients were eligible (TA: n = 162, TNA: n = 96). Without adjustments, TA patients showed significant (p < 0.05) impairments regarding lung function, quality of life and symptom burden. After adjustments, most differences in outcomes were no more significant. Total direct health care costs were reduced but still elevated, with inpatient costs much reduced, while costs of total and respiratory medication only slightly changed. CONCLUSION: Without statistical adjustment, patients with triple therapy showed multiple impairments as well as elevated treatment costs. After adjusting for differences between treatment groups, differences were reduced. These findings are compatible with beneficial effects of triple therapy under continuous, long-term treatment, but also demonstrate the limitations encountered in the comparison of controlled intervention studies with observational studies in patients with severe COPD using different types of devices and compounds.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Humanos , Administração por Inalação , Corticosteroides/uso terapêutico , Agonistas de Receptores Adrenérgicos beta 2/uso terapêutico , Broncodilatadores/uso terapêutico , Efeitos Psicossociais da Doença , Quimioterapia Combinada , Antagonistas Muscarínicos , Qualidade de Vida , Estudos Retrospectivos
6.
J Appl Clin Med Phys ; 25(4): e14300, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38386967

RESUMO

PURPOSE: The aim of this study was to characterize a second-generation wide-detector dual-layer spectral computed tomography (CT) system for material quantification accuracy, acquisition parameter and patient size dependencies, and tissue characterization capabilities. METHODS: A phantom with multiple tissue-mimicking and material-specific inserts was scanned with a dual-layer spectral detector CT using different tube voltages, collimation widths, radiation dose levels, and size configurations. Accuracy of iodine density maps and virtual monoenergetic images (MonoE) were investigated. Additionally, differences between conventional and MonoE 70 keV images were calculated to evaluate acquisition parameter and patient size dependencies. To demonstrate material quantification and differentiation, liver-mimicking inserts with adipose and iron were analyzed with a two-base decomposition utilizing MonoE 50 and 150 keV, and root mean square error (RMSE) for adipose and iron content was reported. RESULTS: Measured inserts exhibited quantitative accuracy across a wide range of MonoE levels. MonoE 70 keV images demonstrated reduced dependence compared to conventional images for phantom size (1 vs. 27 HU) and acquisition parameters, particularly tube voltage (4 vs. 37 HU). Iodine density quantification was successful with errors ranging from -0.58 to 0.44 mg/mL. Similarly, inserts with different amounts of adipose and iron were differentiated, and the small deviation in values within inserts corresponded to a RMSE of 3.49 ± 1.76% and 1.67 ± 0.84 mg/mL for adipose and iron content, respectively. CONCLUSION: The second-generation dual-layer CT enables acquisition of quantitatively accurate spectral data without compromises from differences in patient size and acquisition parameters.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Humanos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Obesidade , Ferro
7.
Eur Radiol ; 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38345607

RESUMO

OBJECTIVES: A prospective, multi-centre study to evaluate concordance of morphologic lung MRI and CT in chronic obstructive pulmonary disease (COPD) phenotyping for airway disease and emphysema. METHODS: A total of 601 participants with COPD from 15 sites underwent same-day morpho-functional chest MRI and paired inspiratory-expiratory CT. Two readers systematically scored bronchial wall thickening, bronchiectasis, centrilobular nodules, air trapping and lung parenchyma defects in each lung lobe and determined COPD phenotype. A third reader acted as adjudicator to establish consensus. Inter-modality and inter-reader agreement were assessed using Cohen's kappa (im-κ and ir-κ). RESULTS: The mean combined MRI score for bronchiectasis/bronchial wall thickening was 4.5/12 (CT scores, 2.2/12 for bronchiectasis and 6/12 for bronchial wall thickening; im-κ, 0.04-0.3). Expiratory right/left bronchial collapse was observed in 51 and 47/583 on MRI (62 and 57/599 on CT; im-κ, 0.49-0.52). Markers of small airways disease on MRI were 0.15/12 for centrilobular nodules (CT, 0.34/12), 0.94/12 for air trapping (CT, 0.9/12) and 7.6/12 for perfusion deficits (CT, 0.37/12 for mosaic attenuation; im-κ, 0.1-0.41). The mean lung defect score on MRI was 1.3/12 (CT emphysema score, 5.8/24; im-κ, 0.18-0.26). Airway-/emphysema/mixed COPD phenotypes were assigned in 370, 218 and 10 of 583 cases on MRI (347, 218 and 34 of 599 cases on CT; im-κ, 0.63). For all examined features, inter-reader agreement on MRI was lower than on CT. CONCLUSION: Concordance of MRI and CT for phenotyping of COPD in a multi-centre setting was substantial with variable inter-modality and inter-reader concordance for single diagnostic key features. CLINICAL RELEVANCE STATEMENT: MRI of lung morphology may well serve as a radiation-free imaging modality for COPD in scientific and clinical settings, given that its potential and limitations as shown here are carefully considered. KEY POINTS: • In a multi-centre setting, MRI and CT showed substantial concordance for phenotyping of COPD (airway-/emphysema-/mixed-type). • Individual features of COPD demonstrated variable inter-modality concordance with features of pulmonary hypertension showing the highest and bronchiectasis showing the lowest concordance. • For all single features of COPD, inter-reader agreement was lower on MRI than on CT.

8.
Diagnostics (Basel) ; 14(3)2024 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-38337796

RESUMO

PURPOSE: To assess the diagnostic accuracy of BMI-adapted, low-radiation and low-iodine dose, dual-source aortic CT for endoleak detection in non-obese and obese patients following endovascular aortic repair. METHODS: In this prospective single-center study, patients referred for follow-up CT after endovascular repair with a history of at least one standard triphasic (native, arterial and delayed phase) routine CT protocol were enrolled. Patients were divided into two groups and allocated to a BMI-adapted (group A, BMI < 30 kg/m2; group B, BMI ≥ 30 kg/m2) double low-dose CT (DLCT) protocol comprising single-energy arterial and dual-energy delayed phase series with virtual non-contrast (VNC) reconstructions. An in-patient comparison of the DLCT and routine CT protocol as reference standard was performed regarding differences in diagnostic accuracy, radiation dose, and image quality. RESULTS: Seventy-five patients were included in the study (mean age 73 ± 8 years, 63 (84%) male). Endoleaks were diagnosed in 20 (26.7%) patients, 11 of 53 (20.8%) in group A and 9 of 22 (40.9%) in group B. Two radiologists achieved an overall diagnostic accuracy of 98.7% and 97.3% for endoleak detection, with 100% in group A and 95.5% and 90.9% in group B. All examinations were diagnostic. The DLCT protocol reduced the effective dose from 10.0 ± 3.6 mSv to 6.1 ± 1.5 mSv (p < 0.001) and the total iodine dose from 31.5 g to 14.5 g in group A and to 17.4 g in group B. CONCLUSION: Optimized double low-dose dual-source aortic CT with VNC, arterial and delayed phase images demonstrated high diagnostic accuracy for endoleak detection and significant radiation and iodine dose reductions in both obese and non-obese patients compared to the reference standard of triple phase, standard radiation and iodine dose aortic CT.

9.
Ann Am Thorac Soc ; 21(3): 438-448, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38206973

RESUMO

Rationale: Primary ciliary dyskinesia (PCD) and cystic fibrosis (CF) are characterized by inherited impaired mucociliary clearance leading to chronic progressive lung disease as well as chronic rhinosinusitis (CRS). The diseases share morphological and functional commonalities on magnetic resonance imaging (MRI) of the lungs and paranasal sinuses, but comparative MRI studies are lacking. Objectives: To determine whether PCD shows different associations of pulmonary and paranasal sinus abnormalities on MRI and lung function test results in children (infants to adolescents) compared with children with CF. Methods: Eighteen children with PCD (median age, 9.5 [IQR, 3.4-12.7] yr; range, 0-18 yr) and 36 age-matched CF transmembrane conductance regulator modulator-naive children with CF (median age, 9.4 [3.4-13.2] yr; range, 0-18 yr) underwent same-session chest and paranasal sinus MRI as well as spirometry (to determine forced expiratory volume in 1 s percent predicted) and multiple-breath washout (to determine lung clearance index z-score). Pulmonary and paranasal sinus abnormalities were assessed using previously validated chest MRI and CRS-MRI scoring systems. Results: Mean chest MRI global score was similar in children with PCD and CF (15.0 [13.5-20.8] vs. 15.0 [9.0-15.0]; P = 0.601). Consolidations were more prevalent and severe in children with PCD (56% vs. 25% and 1.0 [0.0-2.8] vs. 0.0 [0.0-0.3], respectively; P < 0.05). The chest MRI global score correlated moderately with forced expiratory volume in 1 second percent predicted in children with PCD and children with CF (r = -0.523 and -0.687; P < 0.01) and with lung clearance index in children with CF (r = 0.650; P < 0.001) but not in PCD (r = 0.353; P = 0.196). CRS-MRI sum score and mucopyocele subscore were lower in children with PCD than in children with CF (27.5 [26.3-32.0] vs. 37.0 [37.8-40.0] and 2.0 [0.0-2.0] vs. 7.5 [4.8-9.0], respectively; P < 0.01). CRS-MRI sum score did not correlate with chest MRI score in PCD (r = 0.075-0.157; P = 0.557-0.788) but correlated moderately with MRI morphology score in CF (r = 0.437; P < 0.01). Conclusions: MRI detects differences in lung and paranasal sinus abnormalities between children with PCD and those with CF. Lung disease does not correlate with CRS in PCD but correlates in CF.


Assuntos
Transtornos da Motilidade Ciliar , Fibrose Cística , Seios Paranasais , Adolescente , Criança , Lactente , Humanos , Fibrose Cística/complicações , Seios Paranasais/diagnóstico por imagem , Imageamento por Ressonância Magnética , Pulmão/diagnóstico por imagem , Transtornos da Motilidade Ciliar/diagnóstico por imagem
10.
J Cyst Fibros ; 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38218661

RESUMO

INTRODUCTION: Previous studies using magnetic resonance imaging (MRI) demonstrated early onset and progression of chronic rhinosinusitis (CRS) from infancy to school age, and response to lumacaftor/ivacaftor (LUM/IVA) therapy in children with cystic fibrosis (CF). However, the effect of elexacaftor/tezacaftor/ivacaftor (ELX/TEZ/IVA) on CRS detected by MRI in children with CF and at least one F508del mutation, and potential incremental effects of ELX/TEZ/IVA compared to LUM/IVA in F508del homozygous children have not been studied. METHODS: 30 children with CF with at least one F508del mutation underwent three longitudinal paranasal sinus MRI before (MRI1), without (n = 16) or with LUM/IVA therapy (n = 14, MRI2), and with ELX/TEZ/IVA therapy (MRI3, mean age at therapy initiation 11.1 ± 3.4y, range 6-16y). MRI were evaluated using the CRS-MRI score. RESULTS: After therapy initiation with ELX/TEZ/IVA, the prevalence and in maxillary and sphenoid sinuses the dominance of mucopyoceles decreased (35% vs. 0 %, p<0.001 and 26% vs. 8 %, p < 0.05, respectively). This leads to a reduction in mucopyocele subscore (-3.4 ± 1.9, p < 0.001), and sinus subscores in MRI3 (maxillary sinus: -5.3 ± 3.1, p < 0.001, frontal sinus: -1.0 ± 1.9, p < 0.01, sphenoid subscore: -2.8 ± 3.5, p < 0.001, ethmoid sinus: -1.7 ± 1.9, p < 0.001). The CRS-MRI sum score decreased after therapy initiation with ELX/TEZ/IVA by -9.6 ± 5.5 score points (p < 0.001). The strength in reduction of mucopyoceles subscore and CRS-MRI sum score was independent of a pretreatment with LUM/IVA from MRI1-MRI2 (p = 0.275-0.999). CONCLUSIONS: ELX/TEZ/IVA therapy leads to improvement of CRS in eligible children with CF. Our data support the role of MRI for comprehensive monitoring of CRS disease severity and response to therapy in children with CF.

11.
PLoS One ; 19(1): e0291185, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38271373

RESUMO

Since computed tomography (CT) is a part of standard diagnostic protocol in pancreatic ductal adenocarcinoma (PDAC), we have evaluated the value of CT for sarcopenia screening in patients with PDAC, intending to expand the diagnostic value of tomographic studies. In our study, we included 177 patients with available CT images. Two groups were formed: Group 1 consisted of 117 patients with PDAC in various locations and stages and Group 2, or the control group, consisted of 60 "nominally healthy" patients with other somatic non-oncological diseases. The body mass index (BMI) was defined as a ratio of patient's weight to the square of their height (kg/m2). CT-based body composition analysis was performed using commercially available software with evaluation of sarcopenia using skeletal muscle index (SMI, cm2/m2). Based on the SMI values, sarcopenia was found in 67.5% of patients (79 out of 117) in the first patient group. It was found more frequently in males (42 out of 56; 75%) than in females (37 out of 61; 60.6%). Additionally, we observed a decrease in muscle mass (hidden sarcopenia) in 79.7% in patients with a normal BMI. Even in overweight patients, sarcopenia was found in 50% (sarcopenic obesity). In patients with reduced BMI sarcopenia was found in all cases (100%). Statistically significant difference of SMI between two groups was revealed for both sexes (p = 0,0001), with no significant difference between groups in BMI. BMI is an inaccurate value for the assessment of body composition as it does not reflect in the details the human body structure. As SMI may correlate with the prognosis, decreased muscle mass- especially "hidden" sarcopenia or sarcopenic obesity- should be reported. The use of CT-based evaluation of sarcopenia and sarcopenic obesity will allow for a better treatment response assessment in patients with cancer cachexia.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Sarcopenia , Síndrome de Emaciação , Masculino , Feminino , Humanos , Sarcopenia/diagnóstico , Sarcopenia/diagnóstico por imagem , Caquexia/diagnóstico por imagem , Caquexia/etiologia , Detecção Precoce de Câncer , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/patologia , Neoplasias Pancreáticas/complicações , Neoplasias Pancreáticas/diagnóstico por imagem , Obesidade/patologia , Tomografia Computadorizada por Raios X , Carcinoma Ductal Pancreático/patologia , Prognóstico , Síndrome de Emaciação/patologia , Estudos Retrospectivos
12.
Rofo ; 196(2): 134-153, 2024 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-37816377

RESUMO

The process of implementing early detection of lung cancer with low-dose CT (LDCT) in Germany has gained significant momentum in recent years. It is expected that the ordinance of the Federal Ministry for the Environment, Nature Conservation, Nuclear Safety and Consumer Protection (BMUV) on the early detection of lung cancer, which has been commented on by the professional societies, will come into effect by the end of 2023. Based on this regulation, the Federal Joint Committee (G-BA) will set up a program for early lung cancer detection with LDCT in the near future. In this position paper, the specialist societies involved in lung cancer screening present key points for a uniform, structured and quality-assured early detection program for lung cancer in Germany to make a constructive contribution to this process. CITATION FORMAT: · Vogel-Claussen J, Blum TG, Andreas S et al. Position paper on the implementation of a nationally organized program in Germany for the early detection of lung cancer in high-risk populations using low-dose CT screening including the management of screening findings requiring further workup. Fortschr Röntgenstr 2024; 196: DOI 10.1055/a-2178-2846.


Assuntos
Detecção Precoce de Câncer , Neoplasias Pulmonares , Humanos , Tomografia Computadorizada por Raios X , Neoplasias Pulmonares/diagnóstico por imagem , Fatores de Risco , Alemanha , Programas de Rastreamento
13.
Pneumologie ; 78(1): 15-34, 2024 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-37816379

RESUMO

The process of implementing early detection of lung cancer with low-dose CT (LDCT) in Germany has gained significant momentum in recent years. It is expected that the ordinance of the Federal Ministry for the Environment, Nature Conservation, Nuclear Safety and Consumer Protection (BMUV) on early detection of lung cancer, which has been commented on by the professional societies, will come into effect by the end of 2023. Based on this regulation, the Federal Joint Committee (G-BA) will set up a program for early lung cancer detection with LDCT in the near future. In this position paper, the specialist societies involved in lung cancer screening present concrete cornerstones for a uniform, structured and quality-assured early detection program for lung cancer in Germany to make a constructive contribution to this process.


Assuntos
Detecção Precoce de Câncer , Neoplasias Pulmonares , Humanos , Tomografia Computadorizada por Raios X , Neoplasias Pulmonares/diagnóstico por imagem , Fatores de Risco , Alemanha , Programas de Rastreamento
14.
Zentralbl Chir ; 149(1): 96-115, 2024 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-37816386

RESUMO

The process of implementing early detection of lung cancer with low-dose CT (LDCT) in Germany has gained significant momentum in recent years. It is expected that the ordinance of the Federal Ministry for the Environment, Nature Conservation, Nuclear Safety and Consumer Protection (BMUV) on early detection of lung cancer, which has been commented on by the professional societies, will come into effect by the end of 2023. Based on this regulation, the Federal Joint Committee (G-BA) will set up a program for early lung cancer detection with LDCT in the near future. In this position paper, the specialist societies involved in lung cancer screening present concrete cornerstones for a uniform, structured and quality-assured early detection program for lung cancer in Germany to make a constructive contribution to this process.

15.
Magn Reson Imaging ; 105: 75-81, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37939972

RESUMO

PURPOSE: To apply multi-shot high-resolution multi inversion spin and gradient echo (MI-SAGE) acquisition for simultaneous liver T1, T2 and T2* mapping. METHODS: Inversion prepared spin- and gradient-echo EPI was developed with ascending slice order across measurements for efficient acquisition with T1, T2, and T2⁎ weighting. Multi-shot EPI was also implemented to minimize distortion and blurring while enabling high in-plane resolution. A dictionary-matching approach was used to fit the images to quantitative parameter maps, which were compared to T1 measured by modified Look-Locker (MOLLI), T1 measured by variable flip angle (VFA), T2 measured by multiple echo time-based Half Fourier Single-shot Turbo spin-Echo (HASTE), T2 measured by radial turbo-spin-echo (rTSE) and T2⁎ measured by multiple gradient echo (MGRE) sequences. RESULTS: The multi-shot variant of the sequence achieved higher in-plane resolution of 1.7 × 1.7 mm2 with good image quality in 28 s. Derived quantitative maps showed comparable values to conventional mapping methods. As measured in phantom and in vivo, MOLLI, MESE and MGRE give closest values to MISAGE. VFA, HASTE and rTSE show obvious overestimation. CONCLUSIONS: The proposed multi-shot inversion prepared spin- and gradient-echo EPI sequence allows for high-resolution quantitative T1, T2 and T2 liver tissue characterization in a single breath-hold scan.


Assuntos
Fígado , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Fígado/diagnóstico por imagem , Suspensão da Respiração , Imagens de Fantasmas
16.
Eur Radiol ; 2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-38060003

RESUMO

OBJECTIVES: Lung cancer screening (LCS), using low-dose computed tomography (LDCT), can be more efficient by simultaneously screening for chronic obstructive pulmonary disease (COPD) and cardiovascular disease (CVD), the Big-3 diseases. This study aimed to determine the willingness to participate in (combinations of) Big-3 screening in four European countries and the relative importance of amendable participation barriers. METHODS: An online cross-sectional survey aimed at (former) smokers aged 50-75 years elicited the willingness of individuals to participate in Big-3 screening and used analytical hierarchy processing (AHP) to determine the importance of participation barriers. RESULTS: Respondents were from France (n = 391), Germany (n = 338), Italy (n = 399), and the Netherlands (n = 342), and consisted of 51.2% men. The willingness to participate in screening was marginally influenced by the diseases screened for (maximum difference of 3.1%, for Big-3 screening (73.4%) vs. lung cancer and COPD screening (70.3%)) and by country (maximum difference of 3.7%, between France (68.5%) and the Netherlands (72.3%)). The largest effect on willingness to participate was personal perceived risk of lung cancer. The most important barriers were the missed cases during screening (weight 0.19) and frequency of screening (weight 0.14), while diseases screened for (weight 0.11) ranked low. CONCLUSIONS: The difference in willingness to participate in LCS showed marginal increase with inclusion of more diseases and limited variation between countries. A marginal increase in participation might result in a marginal additional benefit of Big-3 screening. The amendable participation barriers are similar to previous studies, and the new criterion, diseases screened for, is relatively unimportant. CLINICAL RELEVANCE STATEMENT: Adding diseases to combination screening modestly improves participation, driven by personal perceived risk. These findings guide program design and campaigns for lung cancer and Big-3 screening. Benefits of Big-3 screening lie in long-term health and economic impact, not participation increase. KEY POINTS: • It is unknown whether or how combination screening might affect participation. • The addition of chronic obstructive pulmonary disease and cardiovascular disease to lung cancer screening resulted in a marginal increase in willingness to participate. • The primary determinant influencing individuals' engagement in such programs is their personal perceived risk of the disease.

17.
Sci Rep ; 13(1): 22745, 2023 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-38123791

RESUMO

In magnetic resonance imaging (MRI), the perception of substandard image quality may prompt repetition of the respective image acquisition protocol. Subsequently selecting the preferred high-quality image data from a series of acquisitions can be challenging. An automated workflow may facilitate and improve this selection. We therefore aimed to investigate the applicability of an automated image quality assessment for the prediction of the subjectively preferred image acquisition. Our analysis included data from 11,347 participants with whole-body MRI examinations performed as part of the ongoing prospective multi-center German National Cohort (NAKO) study. Trained radiologic technologists repeated any of the twelve examination protocols due to induced setup errors and/or subjectively unsatisfactory image quality and chose a preferred acquisition from the resultant series. Up to 11 quantitative image quality parameters were automatically derived from all acquisitions. Regularized regression and standard estimates of diagnostic accuracy were calculated. Controlling for setup variations in 2342 series of two or more acquisitions, technologists preferred the repetition over the initial acquisition in 1116 of 1396 series in which the initial setup was retained (79.9%, range across protocols: 73-100%). Image quality parameters then commonly showed statistically significant differences between chosen and discarded acquisitions. In regularized regression across all protocols, 'structured noise maximum' was the strongest predictor for the technologists' choice, followed by 'N/2 ghosting average'. Combinations of the automatically derived parameters provided an area under the ROC curve between 0.51 and 0.74 for the prediction of the technologists' choice. It is concluded that automated image quality assessment can, despite considerable performance differences between protocols and anatomical regions, contribute substantially to identifying the subjective preference in a series of MRI acquisitions and thus provide effective decision support to readers.


Assuntos
Imageamento por Ressonância Magnética , Humanos , Estudos de Coortes , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Curva ROC , Estudos Longitudinais
18.
Eur Radiol ; 2023 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-38150075

RESUMO

OBJECTIVES: To quantify regional manifestations related to COPD as anomalies from a modeled distribution of normal-appearing lung on chest CT using a deep learning (DL) approach, and to assess its potential to predict disease severity. MATERIALS AND METHODS: Paired inspiratory/expiratory CT and clinical data from COPDGene and COSYCONET cohort studies were included. COPDGene data served as training/validation/test data sets (N = 3144/786/1310) and COSYCONET as external test set (N = 446). To differentiate low-risk (healthy/minimal disease, [GOLD 0]) from COPD patients (GOLD 1-4), the self-supervised DL model learned semantic information from 50 × 50 × 50 voxel samples from segmented intact lungs. An anomaly detection approach was trained to quantify lung abnormalities related to COPD, as regional deviations. Four supervised DL models were run for comparison. The clinical and radiological predictive power of the proposed anomaly score was assessed using linear mixed effects models (LMM). RESULTS: The proposed approach achieved an area under the curve of 84.3 ± 0.3 (p < 0.001) for COPDGene and 76.3 ± 0.6 (p < 0.001) for COSYCONET, outperforming supervised models even when including only inspiratory CT. Anomaly scores significantly improved fitting of LMM for predicting lung function, health status, and quantitative CT features (emphysema/air trapping; p < 0.001). Higher anomaly scores were significantly associated with exacerbations for both cohorts (p < 0.001) and greater dyspnea scores for COPDGene (p < 0.001). CONCLUSION: Quantifying heterogeneous COPD manifestations as anomaly offers advantages over supervised methods and was found to be predictive for lung function impairment and morphology deterioration. CLINICAL RELEVANCE STATEMENT: Using deep learning, lung manifestations of COPD can be identified as deviations from normal-appearing chest CT and attributed an anomaly score which is consistent with decreased pulmonary function, emphysema, and air trapping. KEY POINTS: • A self-supervised DL anomaly detection method discriminated low-risk individuals and COPD subjects, outperforming classic DL methods on two datasets (COPDGene AUC = 84.3%, COSYCONET AUC = 76.3%). • Our contrastive task exhibits robust performance even without the inclusion of expiratory images, while voxel-based methods demonstrate significant performance enhancement when incorporating expiratory images, in the COPDGene dataset. • Anomaly scores improved the fitting of linear mixed effects models in predicting clinical parameters and imaging alterations (p < 0.001) and were directly associated with clinical outcomes (p < 0.001).

19.
Eur Radiol ; 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37870625

RESUMO

OBJECTIVES: The purpose of this study was to determine the influence of dose reduction on a commercially available lung cancer prediction convolutional neuronal network (LCP-CNN). METHODS: CT scans from a cohort provided by the local lung cancer center (n = 218) with confirmed pulmonary malignancies and their corresponding reduced dose simulations (25% and 5% dose) were subjected to the LCP-CNN. The resulting LCP scores (scale 1-10, increasing malignancy risk) and the proportion of correctly classified nodules were compared. The cohort was divided into a low-, medium-, and high-risk group based on the respective LCP scores; shifts between the groups were studied to evaluate the potential impact on nodule management. Two different malignancy risk score thresholds were analyzed: a higher threshold of ≥ 9 ("rule-in" approach) and a lower threshold of > 4 ("rule-out" approach). RESULTS: In total, 169 patients with 196 nodules could be included (mean age ± SD, 64.5 ± 9.2 year; 49% females). Mean LCP scores for original, 25% and 5% dose levels were 8.5 ± 1.7, 8.4 ± 1.7 (p > 0.05 vs. original dose) and 8.2 ± 1.9 (p < 0.05 vs. original dose), respectively. The proportion of correctly classified nodules with the "rule-in" approach decreased with simulated dose reduction from 58.2 to 56.1% (p = 0.34) and to 52.0% for the respective dose levels (p = 0.01). For the "rule-out" approach the respective values were 95.9%, 96.4%, and 94.4% (p = 0.12). When reducing the original dose to 25%/5%, eight/twenty-two nodules shifted to a lower, five/seven nodules to a higher malignancy risk group. CONCLUSION: CT dose reduction may affect the analyzed LCP-CNN regarding the classification of pulmonary malignancies and potentially alter pulmonary nodule management. CLINICAL RELEVANCE STATEMENT: Utilization of a "rule-out" approach with a lower malignancy risk threshold prevents underestimation of the nodule malignancy risk for the analyzed software, especially in high-risk cohorts. KEY POINTS: • LCP-CNN may be affected by CT image parameters such as noise resulting from low-dose CT acquisitions. • CT dose reduction can alter pulmonary nodule management recommendations by affecting the outcome of the LCP-CNN. • Utilization of a lower malignancy risk threshold prevents underestimation of pulmonary malignancies in high-risk cohorts.

20.
Radiologie (Heidelb) ; 63(11): 849-862, 2023 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-37851088

RESUMO

Due to the low proton density of the lung parenchyma and the rapid signal decay at the air-tissue interfaces, for a long time the lungs were difficult to access using magnetic resonance imaging (MRI); however, technical advances could address most of these obstacles. Pulmonary alterations associated with tissue proliferation ("plus pathologies"), can now be detected with high diagnostic accuracy because of the locally increased proton density. Compared to computed tomography (CT), MRI provides a comprehensive range of functional imaging procedures (respiratory mechanics, perfusion and ventilation). In addition, as a radiation-free noninvasive examination modality, it enables repeated examinations for assessment of the course or monitoring of the effects of treatment, even in children. This article discusses the technical aspects, gives suggestions for protocols and explains the role of MRI of the lungs in the routine assessment of various diseases.


Assuntos
Fibrose Cística , Prótons , Criança , Humanos , Fibrose Cística/diagnóstico , Fibrose Cística/patologia , Pulmão/diagnóstico por imagem , Pulmão/patologia , Imageamento por Ressonância Magnética/métodos , Respiração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...